SINGLE CORE FLEXIBLE COPPER CONDUCTOR PVC INSULATED UNSHEATHED INDUSTRIAL WIRING CABLES

Nominal Area of Conductor Number/ Nominal Dia of Wire Thickness of Insulation (Nom.) Approx. Overall Diameter Current carrying capacity for 2 Cables Single Phase AC or DC or 3-Phase AC (unenclosed) Resistance max. per km. at 20C Reference Conductor Class of IS: 8130-1984
(sq.mm) (No./mm) (mm) (mm) (Amps) (Ohms)  
0.5 16/0.2 0.6 2.2 4 39 Class 5
0.75 24/0.2 0.6 2.4 7 26 Class 5
1.0 32/0.2 0.6 2.6 12 19.5 Class 5
1.5 48/0.2 0.6 2.9 16 13.5 Class 5
2.5 80/0.2 0.7 3.5 22 7.98 Class 5
4.0 56/0.3 0.8 4.3 29 4.95 Class 5
6.0 84/0.3 0.8 5.0 37 3.300 Class 5
10.0 140/0.3 1.0 6.3 51 1.910 Class 5
16 126/0.4 1.0 7.3 68 1.210 Class 5
25 196/0.4 1.2 8.9 85 0.780 Class 5
35 276/0.4 1.2 10.1 112 0.554 Class 5
50 396/0.4 1.4 11.9 143 0.386 Class 5
70 360/0.5 1.4 13.6 214 0.272 Class 5
95 475/0.5 1.6 15.8 260 0.206 Class 5
120 608/0.5 1.6 17.5 305 0.161 Class 5
150 750/0.5 1.8 19.5 355 0.129 Class 5
185 925/0.5 2.0 21.5 415 0.1060 Class 5
240 1221/0.5 2.2 25.0 500 0.0801 Class 5
300 1527/0.5 2.4 27.0 580 0.0641 Class 5
400 2036/0.5 2.6 31.0 690 0.0486 Class 5
500 1710/0.6 2.8 34.5 780 0.0384 Class 5

TWO, THREE & FOUR CORE FLEXIBLE COPPER CONDUCTOR PVC SHEATHED CABLES

Nominal
area of
conductor
Number/
Nominal
Dia of
W ire
Thickness
of
Insulation
(Nom)
Thickness
of
Sheath
(Nom)
(2 core)
Thickness
of
Sheath
(Nom)
(3 core)
Thickness
of
Sheath
(Nom)
(4 core)
Approx.
Overall
Diameter
(2 core)
Approx.
Overall
Diameter
(3 core)
Approx.
Overall
Diamerer
(4 core)
Current
Carrying
capacity
for Single
cable for
Single ph
AC or DC
(unenclosed)
Current
Carrying
capacity
for Single
cable for
Three ph
AC
(unenclosed)
Resistance
Max.
per km.
at 20C
Reference
conductor
class of
IS:8130
(Sq.mm) (No/mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (Amps) (Amps) (Ohms)  
0.5 16/0.2 0.6 0.9 0.9 0.9 6.50 7.0 7.5 4 4 39 Class 5
0.75 24/0.2 0.6 0.9 0.9 0.9 7.00 7.5 8.0 7 6 26 Class 5
1.0 32/0.2 0.6 0.9 0.9 0.9 7.25 8.0 8.5 12.5 11 19.5 Class 5
1.5 48/0.2 0.6 0.9 0.9 1.0 7.75 8.5 9.5 15 14 13.5 Class 5
2.5 80/0.2 0.7 1.0 1.0 1.0 9.25 10.25 11.0 20 19 7.98 Class 5
4.0 56/0.3 0.8 1.0 1.0 1.0 10.75 11.75 12.75 27 26 4.95 Class 5
6.0 84/0.3 0.8 1.1 1.3 1.4 12.00 15.0 14.50 35 31 3.300 Class 5
10.0 140/0.3 1.0 1.1 1.4 1.4 14.75 17.5 19.0 46 42 1.910 Class 5
16 126/0.4 1.0 1.2 1.4 1.4 17.00 19.5 21.5 65 57 1.210 Class 5
25 196/0.4 1.2 1.3 1.5 1.6 20.5 23.5 25.5 75 72 0.780 Class 5
35 276/0.4 1.2 1.4 1.6 1.7 23.0 26.5 29.5 100 91 0.554 Class 5
50 396/0.4 1.4 1.6 2.0 2.0 28.0 32.5 35.0 130 120 0.386 Class 5
70 360/0.5 1.4 1.8 2.2 2.2 32.5 38.5 40.0 180 165 0.272 Class 5
95 475/0.5 1.6 1.9 2.4 2.4 38.5 45.0 46.5 220 200 0.206 Class 5
120 608/0.5 1.6 2.0 2.5 2.5 42.5 52.0 52.0 250 225 0.161 Class 5
150 750/0.5 1.8 2.2 2.6 2.6 45.0 52.0 54.0 275 250 0.129 Class 5

FIVE CORE FLEXIBLE COPPER CONDUCTOR PVC SHEATHED CABLES

Nominal area
of conductor
Number/Nominal
Dia of W ire
Thickness of
Insulation
(Nom.)
Thickness of
Sheath
(Nom.)
Approx. overall
Diameter
Current carrying
capacity for single
cable for control
circuits
(unenclosed)
Resistance Max.
per km.
at 20C
Reference
conductor
class of IS:8130
(Sq.mm) (No/mm) (mm) (mm) (mm) (Amps) (Ohms)  
0.5 16/0.2 0.6 0.9 8.50 4 39 Class 5
0.75 24/0.2 0.6 0.9 9.00 6 26 Class 5
1.0 32/0.2 0.6 1.0 9.75 11 19.5 Class 5
1.5 48/0.2 0.6 1.0 10.50 14 13.3 Class 5
2.5 80/0.2 0.7 1.0 12.00 19 7.98 Class 5
4.0 56/0.3 0.8 1.1 14.25 26 4.95 Class 5
6.0 84/0.3 0.8 1.2 16.00 31 3.300 Class 5
10.0 140/0.3 1.0 1.3 19.75 40 1.910 Class 5

PVC FLEXIBLE CABLE

Laser flexible cables are available in single core and multi-core variety. These flexible cables are made from E.C. grade copper having high purity (99.97%), fine wires are drawn and bunched together to make flexible conductor, PVC (Type-A) insulated, multi-core cables are sheathed with PVC (Type-ST1). These cables finds its application in industrial wiring, wiring of panels & other electrical equipments. These cables are designed to withstand 3 KV for 5 minutes or Spark Voltage test as per IS. Governing specification IS 694-1990. Packing – 100 mtr / 200 mtr / 500 mtr or as per customers requirement.